產品: EXCAVATOR
型號: 311B EXCAVATOR 2LS
配置: 311B TRACK-TYPE EXCAVATORS 2LS00001-UP (MACHINE) POWERED BY 3064 ENGINE
故障診斷和排除
Air Conditioning and Heating R134a for All Caterpillar Machines
Automatic Temperature Control System (ECM Controlled) Troubleshooting
SCS - 7309-035-YC; 7610-035-ACD
Automatic Temperature Control Troubleshooting Codes controlled by Machine ECM
Use this procedure to troubleshoot the performance of the HVAC system for machines equipped with automatic temperature control.
Connect Electronic Technician (ET) and check for diagnostics associated with the HVAC system. Refer to the Machine Troubleshooting Guide if any of the following codes are active.
Typical HVAC ET status parameters and values
Symptom Troubleshooting
Cab Temperature is Hig
Probable Causes
? Diagnostic Codes
? Low Pressure Switch / High Pressure Switch
? Low Refrigerant Charge
? Water Valve Actuator
? A/C Compressor
Recommended Actions
Diagnostic Codes
Connect Cat ET to the service tool connector. Check for active diagnostic codes. Look for active codes that are related to the HVAC system in Illustration 1. Use the appropriate circuit test to troubleshoot any active codes before continuing.
Low Pressure Switch / High Pressure Switch
Use Cat ET to monitor the "Air Conditioning Refrigerant Monitoring Circuit" status parameter. With a proper charge the status should be closed. If the status is open, heck the pressure switches and circuit (refer to the pressure switch tests section in this book).
Low Refrigerant Charge
Refer to Air Conditioning Performance - Test
我司主要提供:
柴油零部件,發電機組零部件
總成、缸套組件、活塞組件、四配套、活塞、連桿、活塞銷、曲軸、大修包、渦輪增壓器 、中缸總成、氣缸蓋總成、氣門室蓋、進氣門、排氣門、進氣門座圈、排氣門座圈、門彈簧、氣門鎖片、進、排氣門導管、噴油嘴總成、噴油嘴、柴油泵總成、柱塞、出油閥、進氣支管、排氣支管、缸套、活塞環、連桿瓦、主軸瓦、機油泵總成、機油散熱器、機油散熱器邊蓋、冷卻水箱、上、下水管、風扇葉、正時齒輪室、蓋 、曲軸正時齒輪 隋輪齒、凸輪軸齒、油泵齒、水泵總成、加油馬達、熄火開關、蓄電瓶、軸螺栓、缸蓋螺栓、機油感應器、水溫報警器、聯軸器、高壓油管、接頭、進油管、卡子。
Water Valve Actuator
Test the water value actuator control by switching to heat mode. Use Cat ET and monitor the "Cab Air Heater Engine Coolant Actuator Duty Cycle" status parameter while rotating the temperature dial. The parameter should go to 5% when the temperature dial is full CCW and 95% when the temperature dial is full CW. If the Cab Air Heater Engine Coolant Actuator Duty Cycle" doesn't move with the temperature dial, check the temperature dial (see the troubleshooting section 2661 in the machine troubleshooting guide). If the Cab Air Heater Engine Coolant Actuator Duty Cycle" moves with the temperature dial, verify the water valve actuator circuit and that the actuator is rotating.
A/C Compressor
Switch to AC mode and use Cat ET to monitor the "A/C Compressor" status parameter with the engine running. If the compressor status does not turn to ON after 20 seconds, check the evaporation temperature circuit (refer to 2357 diagnostic code in the machine TSG) and the pressure switch circuits (refer to the pressure switch tests section in this book). If the compressor status is ON and the compressor does not turn on, check for power at the compressor connection.
Note: If the compressor status is on and there is power at the compressor clutch, then replace the
compressor.
Cab Temperature Low
Probable Causes
? Diagnostic Codes
? Water Valve Actuator
Recommended Actions
Diagnostic Codes
Connect Cat ET to the service tool connector. Check for active diagnostic codes. Look for active codes that are related to the HVAC system in Illustration 1. Use the appropriate circuit test to troubleshoot any active codes before continuing.
Water Valve Actuator
Test the water value actuator control by switching to heat mode. Use Cat ET and monitor the "Cab Air Heater Engine Coolant Actuator Duty Cycle" status parameter while rotating the temperature
dial. The parameter should go to 5% when the temperature dial is full CCW and 95% when the temperature dial is full CW. If the Cab Air Heater Engine Coolant Actuator Duty Cycle" doesn't move with the temperature dial, check the temperature dial (see the troubleshooting section 2661 in the machine troubleshooting guide). If the Cab Air Heater Engine Coolant Actuator Duty Cycle" moves with the temperature dial, verify the water valve actuator circuit and that the actuator is rotating.
No airflow from Evaporator Blower Motor
No Auto Blower Control
Perform this test with the key on. Use a 5P-7277 Voltage Tester or use a 9U-7330 Digital Multimeter and connect the negative probe to the pin 7 wire on the control panel using a 7X-1709 Multimeter Probe or equivalent. Check the supply voltage first by connecting the positive probe to the pin 1 wire using a 7X-1708 Multimeter Probe or equivalent. If the system voltage is not measured do not perform any of the other tests below until that is repaired. Select the blower switch to the low speed and connect the positive probe to pin 5 using a 7X-1708 Multimeter Probe or equivalent and record the voltage. For a properly working control panel the voltage should be the same as the system voltage. Repeat for all speeds. Replace the panel if any of the voltages are not present during the test. If the panel passes the test then refer to the machine electrical schematic and check for voltage to the motor and resistor.
Auto Blower Controls
(1) 288-8557 Air Conditioner and Heater Control As - HVAC (Blower Speed)
Perform this test with the key on. Connect ET and look for diagnostics relating to the control panel (2811-3, 2811-4). Use the following procedure to troubleshoot the diagnostics.
Use a 5P-7277 Voltage Tester or use a 9U-7330 Digital Multimeter and connect the negative probe to the pin 6 wire on the control panel using a 7X-1709 Multimeter Probe wire assembly or equivalent and connect the positive probe to the pin 4 wire. Rotate the dial and observe the voltage reading, the voltage should vary between 2 to 4.5 V for a properly working panel.
If the panel passes the test then refer to the machine troubleshooting guide and check for voltage to the motor and driver module if equipped.
- 故障診斷和排除(三十二)卡特礦卡工業機C27發動機總成 售后保障 現貨銷售 2024-11-01
- 故障診斷和排除(三十一)320D2L挖機 發動機總成 缸體 缸蓋 飛輪殼 銷售 性能綜合檢測 2024-11-01
- 故障診斷和排除 (三十) 336挖機發動機 C9.3增壓器 馬達 柴油泵 直供 2024-11-01
- 故障診斷和排除(二十九)礦山挖機維修 保養 零件 空調濾芯 適用336D 374F 390F 2024-11-01
- 故障診斷和排除(二十八)374大挖機 空調系統 C13發動機大修配件 四配套 大小瓦 2024-11-01
- 故障診斷和排除(二十七)帕金斯2806發動機總成 機油冷卻器 機油泵 零件倉庫 售后保障 2024-11-01
- 故障診斷和排除(二十六)C9.3 C15 C13 C18 ECU 電腦板 控制器 2024-11-01
- 故障診斷和排除(二十五)C7.1發動機電噴機 總成 配件 集中 售后條件 2024-11-01
- 故障診斷和排除(二十四)卡特C15發動機 再制造 配件 集合 2024-11-01
- 故障診斷和排除(二十三)珀金斯1104D-E44TA發動機總 售后保障 2024-11-01
- 故障診斷和排除(二十二)發動機 傳感器 電磁閥 電腦板 充電機 起動機 2024-11-01
- 故障診斷和排除(二十一)C7.1發動機總成 售后 2024-11-01
- 故障診斷和排除(二十)適用于所有 Caterpillar 機器的所有空調和暖風用 R134a 產品 2024-11-01
- 故障診斷和排除(十九)適用于所有 Caterpillar 機器的所有空調和暖風用 R134a 產品 2024-11-01
- 故障診斷和排除(十八) 適用于所有 Caterpillar 機器的所有空調和暖風用 R134a 產品 2024-11-01
聯系方式
- 電 話:19079192829
- 市場經理:鄧先生
- 手 機:19079192829
- 微 信:zzzx-3699